| تعداد نشریات | 31 |
| تعداد شمارهها | 825 |
| تعداد مقالات | 7,925 |
| تعداد مشاهده مقاله | 14,584,050 |
| تعداد دریافت فایل اصل مقاله | 9,440,818 |
Impedance-Based Approach for Locating Short-Circuit Faults in Inverter-Based Active Distribution Networks | ||
| International Journal of Industrial Electronics Control and Optimization | ||
| مقاله 6، دوره 7، شماره 3، آذر 2024، صفحه 225-233 اصل مقاله (570.32 K) | ||
| نوع مقاله: Research Articles | ||
| شناسه دیجیتال (DOI): 10.22111/ieco.2024.48761.1569 | ||
| نویسندگان | ||
| Morteza Behbahanipour1؛ Seyed Fariborz Zarei* 1؛ Mohammadhadi Shateri2 | ||
| 1Department of Electrical and Computer Engineering, Qom University of Technology, Qom, Iran | ||
| 2Department of Systems Engineering École de technologie supérieure Montreal, QC, Canada | ||
| چکیده | ||
| This paper proposes an impedance-based approach for locating short-circuit faults in active distribution networks (DNs). This topic is a crucial task for operators, especially in grids with inverter-based distributed generators (IBDGs). Various methods have been proposed in this research area, including traveling waves, impedance-based methods, and artificial intelligence (AI) techniques. Among them, the impedance-based scheme provides a simple and efficient feature that could be used in AI-based techniques. In this paper, an enhanced fault localization method based on impedance estimation is introduced. This method comprises two main components: (i) fault distance determination and (ii) faulty section identification. When developing the proposed method, the modeling of inverter-based resources under symmetrical and asymmetrical faults is considered, which includes the impact and behavior of such sources in the proposed approach. Unlike conventional impedance-based methods, the proposed approach does not require network information such as structure, lines, load data, or voltage and current measurements along the feeder at multiple points. The proposed method can be utilized as a feature in AI-based techniques, significantly enhancing accuracy and reducing the complexity of such techniques. To validate the efficacy of the proposed approach, various series of time-domain case studies are performed, in addition to mathematical proofs. The results demonstrate the effectiveness of the proposed scheme in accurately locating faults with varying resistances at different positions in the presence of inverter-based distributed generators. | ||
| کلیدواژهها | ||
| Active distribution network؛ Fault location؛ Impedance-based approach؛ Inverter-based distributed generation resources | ||
| مراجع | ||
|
[1] Yadegar, M., Zarei, S. F., Meskin, N., & Blaabjerg, F. (2023). A Distributed High-Impedance Fault Detection and Protection Scheme in DC Microgrids. IEEE Transactions on Power Delivery.
[2] Stefanidou-Voziki, P., Sapountzoglou, N., Raison, B., Dominguez Garcia, J.L.: A review of fault location and classification methods in distribution grids. Electr. Power Syst. Res. 209, 108031 (2022). [3] S. Gururajapathy, H. Mokhlis, and H. Illias, "Fault location and detection techniques in power distribution systems with distributed generation: A review," Renewable and Sustainable Energy Reviews, vol. 74, pp. 949-958, 2017. [4] Jun Zhu, D. L. Lubkeman and A. A. Girgis, "Automated fault location and diagnosis on electric power distribution feeders," in IEEE Transactions on Power Delivery, vol. 12, no. 2, pp. 801-809, April 1997, doi: 10.1109/61.584379 . [5] Seung-Jae Lee et al., "An intelligent and efficient fault location and diagnosis scheme for radial distribution systems," in IEEE Transactions on Power Delivery, vol. 19, no. 2, pp. 524-532, April 2004, doi: 10.1109/TPWRD.2003.820431. [6] X. Yang, M. Choi, S. Lee, C. Ten and S. Lim, "Fault Location for Underground Power Cable Using Distributed Parameter Approach," in IEEE Transactions on Power Systems, vol. 23, no. 4, pp. 1809-1816, Nov. 2008, doi: 10.1109/TPWRS.2008.2002289 . [7] H. Nouri and M. M. Alamuti, "Comprehensive Distribution Network Fault Location Using the Distributed Parameter Model," in IEEE Transactions on Power Delivery, vol. 26, no. 4, pp. 2154-2162, Oct. 2011, doi: 10.1109/TPWRD.2011.2161620. [8] R. H. Salim, M. Resener, A. D. Filomena, K. R. C. De Oliveira, and A. S. Bretas, "Extended fault-location formulation for power distribution systems," IEEE Transactions on Power Delivery, vol. 24, no. 2, pp. 508-516, 2009. [9] A. S. Bretas and R. H. Salim, "Fault Location in Unbalanced DG Systems using the Positive Sequence Apparent Impedance," 2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America, 2006, pp. 1-6, doi: 10.1109/TDCLA.2006.311611. [10] R. H. Salim, K. R. C. de Oliveira, A. D. Filomena, M. Resener and A. S. Bretas, "Hybrid Fault Diagnosis Scheme Implementation for Power Distribution Systems Automation," in IEEE Transactions on Power Delivery, vol. 23, no. 4, pp. 1846-1856, Oct. 2008, doi: 10.1109/TPWRD.2008.917919. [11] J. U. N. Nunes and A. S. Bretas, "Impedance-based fault location formulation for unbalanced primary distribution systems with distributed generation," 2010 International Conference on Power System Technology, 2010, pp. 1-7, doi: 10.1109/POWERCON.2010.5666589. [12] K. Ramar and E. E. Ngu, "A new impedance-based fault location method for radial distribution systems," IEEE PES General Meeting, Minneapolis, MN, USA, 2010, pp. 1-9, doi: 10.1109/PES.2010.5588189. [13] R. Krishnathevar and E. E. Ngu, "Generalized ImpedanceBased Fault Location for Distribution Systems," in IEEE Transactions on Power Delivery, vol. 27, no. 1, pp. 449-451, Jan. 2012, doi: 10.1109/TPWRD.2011.2170773. [14] S. F. Alwash, V. K. Ramachandaramurthy and N. Mithulananthan, "Fault-Location Scheme for Power Distribution System with Distributed Generation," in IEEE Transactions on Power Delivery, vol. 30, no. 3, pp. 1187-1195, June 2015, doi: 10.1109/TPWRD.2014.2372045 [15] F.M. Aboshady, D.W.P. Thomas, Mark Sumner, A new single end wideband impedance based fault location scheme for distribution systems, Electric Power Systems Research, Volume 173, 2019, Pages 263-270, ISSN 0378-7796, https://doi.org/10.1016/j.epsr.2019.04.034 [16] H. Mirshekali, R. Dashti, A. Keshavarz, A. J. Torabi and H. R. Shaker, "A Novel Fault Location Methodology for Smart Distribution Networks," in IEEE Transactions on Smart Grid, vol. 12, no. 2, pp. 1277-1288, March 2021, doi: 10.1109/TSG.2020.3031400. [17] Morteza Behbahani poor, and Seyed Fariborz Zarei, “A Fault Location Scheme for Distribution Networks with InverterBased Resources,” presented at the POWER ELECTRONICS AND DRIVES: SYSTEMS AND TECHNOLOGIES CONFERENCE PEDSTC. 2024, [Online]. Available: https://sid.ir/paper/1132495/en [18] Zarei, Seyed Fariborz, Hossein Mokhtari, and Frede Blaabjerg. "Fault detection and protection strategy for islanded inverterbased microgrids." IEEE Journal of Emerging and Selected Topics in Power Electronics 9.1 (2019): 472-484. [19] Zarei, Seyed Fariborz, Mohamad Amin Ghasemi, and Saeed Khankalantary. "Current limiting strategy for grid-connected inverters under asymmetrical short circuit faults." International Journal of Electrical Power & Energy Systems 131 (2021): 107020. [20] D. Tzelepis, A. O. Rousis, A. Dyśko, C. Booth, and G. Strbac, "A new fault-ride-through strategy for MTDC networks incorporating wind farms and modular multi-level converters," International Journal of Electrical Power & Energy Systems, vol. 92, pp. 104- 113, 2017. [21] Du, Y. Liu, G. Wang, P. Sun, H.-M. Tai, and L. Zhou, "Three?phase grid voltage synchronization using sinusoidal amplitude integrator in synchronous reference frame," International Journal of Electrical Power & Energy Systems, vol. 64, pp. 861-872, 2015. [22] A. Yazdani and R. Iravani, Voltage-sourced converters in power systems: modeling, control, and applications: John Wiley & Sons, 2010. [23] F. Blaabjerg, R. Teodorescu, M. Liserre, and A. V. Timbus, "Overview of control and grid synchronization for distributed power generation systems," IEEE Transactions on industrial electronics, vol. 53, no. 5, pp. 1398-1409, 2006. [24] R. Teodorescu, M. Liserre, and P. Rodriguez, Grid converters for photovoltaic and wind power systems vol. 29: John Wiley & Sons, 2011. [25] J. Jia, G. Yang, and A. H. Nielsen, "A review on grid-connected converter control for short-circuit power provision under grid unbalanced faults," IEEE Transactions on Power Delivery, vol. 33, no. 2, pp. 649-661, 2017. [26] Zarei, Seyed Fariborz, et al. "A Fault Detection Scheme for Islanded-Microgrid with Grid-Forming Inverters." 2021 6th IEEE Workshop on the Electronic Grid (eGRID). IEEE, 2021. [27] Zarei, Seyed Fariborz, and Mostafa Parniani. "A comprehensive digital protection scheme for low-voltage microgrids with inverter-based and conventional distributed generations." IEEE Transactions on Power Delivery 32.1 (2016): 441-452. [28] W. H. Kersting, Distribution System Modeling and Analysis, Boca Raton, FL: CRC, 2002. [29] A. Gopi and P. A. D. V. Raj, ”Distributed generation for line loss reduction in radial distribution system” proc.- ICETEEEM 2012, Int. Conf.Emerg. Trends Electr.Eng. Energy Manag., pp. 29-32,2012. [30] Kawambwa, S., Mwifunyi, R., Mnyanghwalo, D. et al. An improved backward/forward sweep power flow method based on network tree depth for radial distribution systems. Journal of Electrical Systems and Inf Technol 8, 7 (2021). https://doi.org/10.1186/s43067-021-00031-0 [31] Mathworks Matlab. Natick, MA, 2009. [Online]. Available: http://www.mathworks.com | ||
|
آمار تعداد مشاهده مقاله: 319 تعداد دریافت فایل اصل مقاله: 255 |
||